TSQ Certis Triple Quadrupole


Thermo Scientific™ TSQ Certis™ Mass Spectrometer is designed for laboratories requiring high sensitivity, reproducibility, and efficient processing of large sample batches. Building on TSQ Altis Plus technology, it incorporates advanced ionization and ion-transfer components to support consistent analytical performance while limiting contamination.

High-speed SRM acquisition and short transition dwell times support multi-compound quantitative methods and narrow UHPLC peaks. Quadrupole settings down to 0.2 Da FWHM provide additional selectivity in the presence of interfering compounds.

The optimized ion path includes an electrodynamic ion funnel, a Q00 ion guide with mass-filtering capability, and a Q0 active ion beam guide with a neutral blocker. These components promote efficient ion transmission while reducing contamination of the analytical region. QR5 Plus segmented quadrupole mass filters and the ARC™ II collision cell complete the architecture for rapid, sensitive quantitation.

The OptaMax Plus ion source supports HESI and APCI, with vaporizer temperatures up to 650°C. Adjustable sprayer positioning facilitates ionization optimization for the application.

An early warning system provides calibration-time and run-time notifications to support maintenance planning. Chromeleon™ CDS and TraceFinder™ software provide instrument control, data processing, and reporting capabilities, while built-in application templates in the instrument software simplify method setup.

Combined with Vanquish™ UHPLC systems, appropriate sample preparation, and application-specific columns, TSQ Certis supports integrated solutions for pharmaceutical and biopharmaceutical analysis, clinical research, toxicology, food safety testing, and environmental analysis.


Key technical specifications

Parameter Specification
Mass spectrometer type Triple quadrupole LC-MS/MS
Mass range m/z 2–2010
Q1 and Q3 peak widths Settings of 0.2, 0.4, 0.7, 1.2, and 2.0 Da FWHM
SRM acquisition rate Greater than 900 SRM transitions/s, according to the technical specification
Minimum SRM dwell time 0.25 ms
Scan speed Up to 20,000 Da/s in Full Scan Q3 mode at 2 Da FWHM
Polarity switching Less than 5 ms
Linear dynamic range Greater than six orders of magnitude
Ion source OptaMax Plus, supporting HESI and APCI
Maximum vaporizer temperature 650°C
Software compatibility Chromeleon CDS, TraceFinder, Xcalibur, and FreeStyle; compatibility with the mzCloud database
Mass spectrometer weight 112 kg
Liquid Chromatography
Ion Chromatography
Gas Chromatography
Chromatography Sample Preparation
Chromatography Software
Chromatography Columns and Consumables
LC MS – Liquid Chromatography Mass Spectrometry
GC MS - Gas Chromatography Mass Spectrometry
IC-MS – Ion Chromatography Mass Spectrometry
ICP-MS – Inductively Coupled Plasma Mass Spectrometry
IRMS - Isotope ratio Mass spectrometry
GD-MS – Glow Discharge Mass Spectrometry
Process Mass Spectrometry
MS Software – Mass Spectrometry Software
Infrared Spectrometers and Microscopes FT-IR
Near Infrared Analyzers NIR
Raman Spectrometers and Microscopes
Portable Spectrometers for Identification
FT-IR accessories
UV-VIS Spectrophotometers
DIA – Complex analyzers
Pharamaceutical Testing Equipment
Laboratory Systems for Pure and UltraPure Water
Sample Preparation Systems
Gas Generators
Laboratory Equipment

Copyright © ACM2 2026